Dear Mr. Lishey,
This is in response to your letter requesting clarifications on 1910.146,
Permit Required Confined Spaces.
1910.146(k)(3) requires that retrieval systems be used except when the
retrieval equipment would increase the risk to an entrant or would not
contribute to the rescue of an entrant. When a retrieval system is not
used, alternate methods of retrieval must be developed, and rescue personnel
must be trained in retrieving the entrant in the event of an emergency.
The code does not prohibit a confined space being reconfigured to facilitate
non-entry removal of an entrant.We hope this answers your question regarding
confined spaces. If you have any questions or if we can be of further
assistance, please contact David
McLaughlin at (503) 378-3272.
Sincerely,
Marilyn K. Schuster, Manager
Standards and Technical Resources Section